Product Detail

Model No.: On-line
Production Capacity: 5000 pieces / month
Delivery Date: 7-15 days after the order c...
Disc Diameter: 125mm
Rated Voltage: 220
Rated Input Power: 24
Dimensions: 500*200
Measuring Range: See selection specification...
Power Range: 12V-45V
Resolution: 0.001g/cm³
Power Influence: <0.005%/V of output rang...
Means of Transport: Ocean,Land,Air
Packing: Carton box, gift box, or ac...
Disc(Wheel) Type: Grinding Disc
Brand Name: MOre
Frequency: 50000
No-Load Speed: 6230
Using objects: Liquid
Power: external supply 24V dc
Accuracy: 0.2%, 0.5%
Stability: The maximum range is ±0.25%...
Starting Time: 3s, no preheating

The instrument can be real-time online measured the density for all liquids or fluid mixtures.

Product Introduction
 

The instrument can be real-time online measured the density for all liquids or fluid mixtures. In petrochemical industry, it can be widely used in oil, oil refinery, oil water interface measurement. In the food industry, it can be used in production sites for grape juice, tomato juice, fruit syrup, vegetable oils and the processing of soft drinks etc. even in the dairy industry, the paper industry. It can be tested by the black pulp, green pulp, white pulp and alkaline aqueous. It can also be applied in salt mining potash, potassium carbonate, natural gas, lubricant oil, biopharmaceutical etc.


Features


1.Using the unitized structure transducer with double-line, no moving parts and simple maintenance.
2.5 digit liquid crystal display (LCD) and backlight can be clearly showed in the dark.
3.Install and use conveniently, insert the liquid to display readings or use the external type.
4.Using the fluid or still fluid, it is suitable for the installation of pipes and tanks.
5.Can be online measured the liquid density continuously, no process interruption. Can be directly used in the production process control.
6.The all parts where touched the liquid are several kinds of medium that are made by stainless steel or special materials. Safety and health.
7.Health types can be installed in the field of food production.
8.The safety and explosion-proof types can be both selected. Can be used in dangerous.


Technical Performance


Using objects: Liquid
Measuring Range: See selection specification table
Output Signal: 4~20mA dc output, overlap HART agreement, digital signals (double lines)
Power: external supply 24V dc.
Power Range: 12V~45V
The Installation of Dangerous Sites:
Explosion-proof type   dIICT5
Intrinsic safety type    iaIICT5
Migration Features: Installed through the buttons or hand operator communication interface for migration.
Temperature Range:
Printed Circuit Board(PCB) -40~85℃
Sensitive Components  -40~300℃
Storage Temperature   -40~85℃
Digital Display  -25~65℃ (Normal Operation)
-40~85℃ (No Damage)
Relative Temperature:0~95%
Overpressure Limit:
In line with the flange pressure level, sensor add 0 (Absolute Pressure) ~13Mpa, the pressure transmitter
(No Damage);
Damping: Time constant between 0.2~32.0s is adjustable.
Starting Time: 3s, no preheating.
Technique Index
(In the conditions of no migration, 316 stainless steel isolation diaphragm and other standard tests.)
Accuracy: 0.2%, 0.5%
Resolution: 0.001g/cm³
Stability: The maximum range is ±0.25%/6 months
Temperature Influence: zero point error is the maximum range 1%/55℃
Power Influence: <0.005%/V of output range.
Vibration Influence: In any direction of axis, frequency is 200Hz, the error is the maximum range ±0.05%/g.
Load Influence: only the pressure of input transducer is high to 12V, there is no loading effect in the working area of load.
Installation Position Influence:  Because of themselves pressure medium, the position of installation will
make great impact. It can not be corrected by the way of zero, but no influence after correction.


Application


1.The principle of on-line densimeter is a kind of differential pressure method based on the double probe that can be measured accurately. So just make sure the double probe is fully immersed, then the static pressure is stable, even if it is stired constantly. It is suitable for equipment of testing density. If there are some bubbles that can influence the density, should be added some testing pots on the unsuitable for direct measurement.
2.The installation drawing will be decided by the technicians in work site according to the equipments sizes.
3.It should be added some testing pots when the flowing liquids or larger vibration liquids were tested, in order to reduce bubbles that can make the reading stability. The field operator adjust the flow of liquid in the testing pot that should be refered the two readings of dynamic and stability.
4.When install the density meters on site that must be make sure the two probes are vertical the ground, then can make measurement errors.
The density meters can be tested the concentration according to different mediums academically, please according to the site conditions to get the concentration results on its own.


bigPhoto
 Ms. Amanda

Tel: 86-29-89388792
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Shaanxi sensing technology co., LTD [China (Mainland)]


Business Type:Manufacturer
City: Xi'an
Province/State: Shaanxi
Country/Region: China (Mainland)

You May Like:

Product (10)